0419-3990000

Analysis of Normal Pressure Range for LNG Storage Tanks

Industry News · 2026-11-16 01:17:19

Analysis of Normal Pressure Range for LNG Storage Tanks

Pressure control in LNG storage tanks is critical for safe and stable operation. For example, in LNG vehicle refueling stations, precise management of tank pressure directly impacts refueling efficiency and vehicle safety. Determining the normal pressure range for LNG storage tanks requires an in-depth analysis of design specifications and actual operating conditions.

Design pressure standards for tanks

The design pressure of storage tanks must comply with the specifications of GB/T 18442 series standards. Based on GB/T 18442.1-2019《Liquefied Natural Gas (LNG) Production, Storage and Transportation》, this standard defines requirements for the design, manufacturing, and inspection of LNG storage tanks and facilities. GB/T 18442.3-2019《Fixed Vacuum Insulated Cryogenic Pressure Vessels Part 3: Design》 further specifies methods for determining design pressure, including allowable stress, wall thickness calculations, and structural strength verification. These standards ensure the reliability of tanks under extreme low temperatures and high pressures. For instance, according to GB/T 18442.3-2019, 30-150m³ LNG storage tanks typically have a design pressure of 0.6MPa or 0.8MPa, with specific values determined by actual conditions and medium characteristics.

Actual operating pressure influenced by medium and conditions

The actual operating pressure of storage tanks must account for the physical properties of LNG and usage requirements. LNG has extremely low saturation pressure at -162°C, but actual operation must overcome factors such as vaporization heat, ambient temperature changes, and pressure fluctuations. According to GB/T 18442.4-2019《Fixed Vacuum Insulated Cryogenic Pressure Vessels Part 4: Manufacturing》, tank manufacturing must ensure material stability at low temperatures. Additionally, GB/T 18442.5-2019《Fixed Vacuum Insulated Cryogenic Pressure Vessels Part 5: Inspection and Testing》 mandates pressure and leak tightness tests to verify tank sealing under operating pressure. In practice, tank pressure dynamically adjusts due to unloading, refueling equipment operation, or temperature changes, but must always remain below the design pressure limit.

Correlation between pressure range and tank volume

The volume specification of storage tanks is related to their standard working pressure setting. According to GB/T 18442.2-2019《Fixed Vacuum Insulated Cryogenic Pressure Vessels Part 2: Materials》, different volume tanks require suitable inner vessel materials, such as S30408 or 9%Ni steel for 1m³~200m³ tanks. Taking 20-150m³ LNG storage tanks as an example, their design pressure is typically 0.6MPa or 0.8MPa. Furthermore, the configuration of Ambient Air Vaporizer (working pressure 0.8~3.5MPa) indirectly affects the pressure requirements of storage tanks, requiring comprehensive system design consideration. On-site verification of actual operating pressure within the design range is essential.